CHAPTER ONE
INTRODUCTION
A transformer is a magnetically coupled coil used in transmission of an electric power.
This coil may be electrically link, but not electrically linked as in two winding transformer.
It consists of primary winding and secondary winding which the
number of turns varies depending on the type of transformer.
Transformers are operated by the principle of mutual inductance between
two separate coils wound on the same core.
There is also the step – up and step – down transformer. This work looks into the construction of a step – up auto transformer.
auto – transformer is the transformer that consists of only one is winding port of the being common to both primary winding and secondary winding.
That theory of an auto transformer and it operation is similar to that of the two winding transformer, it has high efficiency where cheap (because it used less copper) it is applicable where transformer ratio is little differs from unity.
- STANDARD WIRE GUAGE: These are specific number of a wine (coil) it is used in this project to gauge on 17 which has a diameter of 1.422m.
- TRANSFORMER: It is a cutout shape rubber material with a hollow in the center and with grove around is to avoid electrical link between the core and the coil.
- VOLTMETER: This is the instrument used to measure the voltage across the circuit. It is connected in parallel to the winding
- INSULATOR: These are the material used to isolate two conductors from touching each other.
1.2 PURPOSE
This transformer is a step – up transformer, it help in stepping
up voltage, because of the primary winding function and the secondary
winding function from the voltage rating to the normal rating is to
step – up voltage in the transformer.
1.3 OBJECTIVE
This transformer consists of only one winding part of the common
to both primary and secondary winding. It had high efficiency and uses
less copper, it is applicable where transformer ratio is differ from
unity. The primary winding is connected to the power source and the
other winding are secondary winding it help the transformer in increase
the voltage to the normal voltage rate.
1.4 SIGNIFICANCE
The R. Fienberg in “MODERN POWER TRANSFORMER PRACTICE”
stated that a transformer has a significance rate that transformer
machine in bringing down the voltage rate it’s the desire amount.
Transformer initially raises the generated voltage for efficient
transmission over long distance and there after decrease the system
voltage for local destruction and utilization.
1.5 LAMINATION
The transformer comprises of ‘E’ and ‘I’ laminated cores which
was obtained from a scrub transformer and recycled. the process of
recycling involve washing of core with fuel to removed the unwanted
grease and then dry up and grease with new oil so as to prevent air gap.
it also comprise of coil which bought fresh one in the market,
switches, connector former and insulator to isolate the output and
input wires from touching each others.
1.6 DEFINITIONS OF TERMS
a transformer is a magnetically coupled with coil as in show in
fig.1.1, a transformer rescues input current and send output voltage,
be it step – up or step – down transformer it used in transmission of
an electric power.
1.6.1 STANDARD WIRE GUAGE:
These are specific number of a wine (coil) it is used in this project to gauge on 17 which has a diagram of 1.422m.
1.6.2 TRANSFORMER:
It is a cutout shape rubber material with a hollow in the center
and with grove around is to avoid electric link between the core and
the coil.
1.6.3 VOLTMETER:
This is the instrument used to measure the voltage across the circuit. It is connected in parallel to the winding.
1.6.4 INSULATOR:
These are the material used to isolate two conductors from touching each other.
1.6.5 CASING:
The outer cover of the transformer this serve is from external
hazard was made of metal as earlier stated in our previous chapter.
1.6.6 THE SWITCH:
This is a mechanical advice used to open and close a complete
electric circuit. The multipurpose low voltage (AC) transformers are
connected via switch to the power supply.
The primary winding is connected to the power source and the other winding are secondary winding
We have step – up transformer and step – down transformer. But
in this context emphasis will be lay on the step – up auto transformer.
You either get what you want or your money back. T&C Apply
You can find more project topics easily, just search
-
SIMILAR ELECTRICAL ENGINEERING FINAL YEAR PROJECT RESEARCH TOPICS
-
1. DESIGN AND CONSTRUCTION OF A SINGLE PHASE AUTO-TRANSFORMER OF RATING IKVA, 240V/110, 80 12V, 6V
» ABSTRACT This project work up deals on the design and construction of a single phase step down nations fermor, with raking IKVA, 240V/11OV, 80V 12U, 6...Continue Reading »Item Type & Format: Project Material - Ms Word | 50 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
2. DESIGN AND IMPLEMENTATION OF A SOFTWARE PACKAGE FOR BILLING SYSTEMS OF ELECTRICITY INDUSTRY
» CHAPTER ONE INTRODUCTION 1.1 BACKGROUND OF STUDY The Automated Meter Reading (AMR) was started in 1962 by AT&T, but this experiment was not succes...Continue Reading »Item Type & Format: Project Material - Ms Word | 35 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
3. DESIGN OF AN EQUIPMENT THAT CAN FACILITATE A CONVENIENT AND EASY WAY OF CONTROLLING OUR DOMESTIC APPLIANCES
» CHAPTER ONE INTRODUCTION 1.1 OBJECTIVE OF PROJECT The need for a remote control alert system that can control domestic appliances and various lighting...Continue Reading »Item Type & Format: Project Material - Ms Word | 84 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
4. EXPERT SYSTEM FOR LOCAL AREA NETWORK TROUBLESHOOTING
» ABSTRACT This work is designed to provide assistance in engaging and overcoming challenges involved in troubleshooting and maintenance of local area n...Continue Reading »Item Type & Format: Project Material - Ms Word | 135 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
5. THE EFFECT OF TEACHER-STUDENTS RELATIONSHIP ON STUDENTS ACADEMICS PERFORMANCE IN SOME SELECTED TECHNICAL COLLEGES IN NIGER AND KADUNA STATE
» TABLE OF CONTENTS Title page i Approval page ii Declaration iii Dedication iv Acknowledgement v Table of contents vi Abstract viii CHAPTER ONE : INTRO...Continue Reading »Item Type & Format: Project Material - Ms Word | 52 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
6. CONSTRUCTION OF A FREQUENCY TO VOLTAGE CONVERTER
» ABSTRACT The project is aimed at constructing a frequency to voltage transducer circuit. The method of constructing this circuit is first simulated on...Continue Reading »Item Type & Format: Project Material - Ms Word | 23 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
7. CONSTRUCTION OF AUTOMATIC WATER LEVEL CONTROLLER FOR BOTH OVERHEAD AND UNDERGROUND TANKS
» CHAPTER ONE INTRODUCTION 1.0 BACKGROUND The project “automatic water level control with an automatic pump control system” is design to mon...Continue Reading »Item Type & Format: Project Material - Ms Word | 70 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
8. TO HARNESS THE ABUNDANT AND FREE SOLAR ENERGY DURING THE DAY TIME AND CONVERT IT TO ELECTRICAL ENERGY THAT WILL BE USED TO POWER SOME COMPONENTS OF AN...
» CHAPTER ONE 1.0 BACKGROUND OF STUDY A solar cell is an electronic device that converts the sunlight energy directly into electric energy without any f...Continue Reading »Item Type & Format: Project Material - Ms Word | 51 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
9. A STUDY OF WIND POWERED TURBINE GENERATION
» ABSTRACT The (PHCH) Power Holding Company of Nigeria Plc, effort to provide us with a regular power supply has not yet been achieved. And it is becaus...Continue Reading »Item Type & Format: Project Material - Ms Word | 52 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT
-
10. The design, construction and test on a two station simple intercom system
» CHAPTER ONE: INTRODUCTION 1.1 INTRODUCTION / BACKGROUND Human to human communication is an essential part of our every day activities. Advances in com...Continue Reading »Item Type & Format: Project Material - Ms Word | 50 pages | Instant Download | Chapter 1-5 | ELECTRICAL ENGINEERING DEPARTMENT